Refer to the following tables for the description of each error code. Il climatizzatore inizia a funzionare correttamente ma dopo qualche minuto si stacca e sul display compare la scritta EC. * Kindly Mark and Vote this reply if it helps, as it will be beneficial to more community members reading here. 2) Press the set temperature buttons simultaneously for 5 seconds or more to start the self-diagnosis. There has been a power surge in the system. Attendo risposta to perform the self-diagnosis. REMOTE CONTROLLER DISPLAY. E2 Outdoor pipe (coil) temperature sensor (OPT) RUN-3/8 sec. Panasonic h12 error code Hi, I have a aquastar 2400E/NG tankless water heater and it got flooded through the exhaust vent with water and now it's giving me a code of EC ⦠Descrivi la tua richiesta (non inserire adesso i tuoi dati di contatto): Si tratta di un climatizzatore monosplit Comfee. The units are not wired properly, or the wiring is damaged. 1) Stop the air conditioner operation. E6 Power off the unit and turn off the breaker or disconnect. How To Clear an E4, E5, E6, F1, F2, F3 Error Codes on a Mini Split . E5 Indoor fan motor fault RUN-6/8 sec. SAMSUNG SPLIT-TYPE AIR CONDITIONER SERVICE TROUBLESHOOTING MANUAL IN PDF SAMSUNG SPLIT-TYPE AIR CONDITIONER SERVICE MANUAL â PDF 1. Marketing and analytics cookies. outdoor communication fault RUN & TIMER: Blink EC Room temperature sensor (IRT) RUN-1/8 sec. Error due to mismatching capacity of indoor and outdoor unit: E557: DPM remote controller option error: E560: Switch option setting error(rvot applied) E590: Inverter EEPROM Checksum error: E660: Error of inverter Boot Code: P701: Indoor unit floating S/V error(When 1â detection) P702: Indoor unit EEV close failure(When 1â detection) P703 E3 System abnormal RUN-4/8 sec. Non raffredda, quindi va in blocco e compare il codice EC, dovrebbe trattarsi di una perdita nel sistema del gas refrigerante. E:EE indicates an error has occurred. Symptom: Operation is delayed a few minutes after restarting Cause: The delay is a protection to the unitâs compressor. Symptom: Airflow continues even after operation has stopped Cause: Extraction of remaining heat from the indoor unit (maximum 30 seconds). We would like your consent to collect this data to help us tailor the marketing you see. Samsung Split System Air Conditioning Outdoor Unit Diagram . This type of error appears when the system fails to monitor the exchange of data between the units or between their components and the PCBs. Reset the Control Panel: Like a computer's memory chip or a DSL modem, an air conditioner control panel gets corrupted by continuous use and has to be reset.For GE models, as well as others, all you have to do is unplug the unit, leave it unplugged for at least 1 minute, and plug it back in. -----Beware of scammers posting fake support numbers here. Wait 2-3 minutes and power the unit back on. E1 Indoor pipe (coil) temperature sensor (IPT) RUN-2/8 sec. Any problem that is not fixed will likely come back. If have a mini split unit that gives an E4, E5, E6, F1, F2, F3 error code a few things can cause this problems. This happens because: The PCBs in the indoor and outdoor units have gone faulty. E4 Model configuration wrong RUN-5/8 sec.