Check the drain sensor heater. If this reoccurs, contact your local authorised service centre. Below are 2 tables from which you can see Whirlpool air conditioner error codes. Coming-off, disconnection or short of indoor heat exchanger temp. of connected outdoor units decreased. Freezing protection/ overheating protection is working. 2) Indoor ambient temperature sensor damaged. These cookies will be stored in your browser only with your consent. Indoor Coil Temperature Sensor Malfunction. The technician check & simply changed Motor, then it working and charged my huge amount • Check the contact of P.C. • If the water tank is full the warning sign "H8” appears in the display. We also use third-party cookies that help us analyze and understand how you use this website. • Check the characteristic of the discharge temperature thermistor. You will save time and money without the help of a repairman. After address setup, communication from all the indoor units interrupted under condition that a normal operation can be performed. • This procedure is completely normal and protects the system from icing and failure. The compressor stops when a short or open circuit occurs in the evaporation temperature thermistor during compressor running. A hissing sound can be made when the air conditioner is switched to defrosting operation during heating operation. When the fin temperature thermistor detects 89°C or above, the compressor stops and restarts operation in 3 minutes. The indicator turns on and off (1 Hz) when power is restored after a power failure or when the power main switch is set to on. He has 33 years of experience troubleshooting and repairing all types of appliances.Contact here Compressor 1 high pressure trip / contact open, Compressor 2 hiqh pressure trip / contact open, Compressor 3 high pressure trip / contact open, Compressor 4 hiqh pressure trip / contact open, Compressor 1 trip / low R-22 / outdoor abnormal, Compressor 2 trip / low R-22 / outdoor abnormal, Compressor 3 trip / low R-22 / outdoor abnormal, Compressor 4 trip / low R-22 / outdoor abnormal, Room air sensor contact loose / short Outdoor coil sensor contact loose / short. The use by Actron air error codes makes it easier. Please switch the unit off and start it again after approx. Further, the user himself or a service center specialist possessing the information reported by the air conditioner, founds ways of the error removal. Frequency drop by high pressure switch protection. If "F2" continues to appear call to arrange for product inspection and repair. • Check the indoor unit air filter for clogging. They switch the power supply “off” then “on” and the system works for a while then goes into a fault mode again. The compressor stops when a short or open circuit occurs in the fin temperature thermistor during compressor running. There are derivative models, e.g. Attach the hose or remove the obstruction. No connection between multiple refrigerant lines: SW30 bit 20N, Connection between multiple refrigerant lines: SW30 bit 2 of the connected header unit is turned. P1 - funzione di DEFROSTING attiva: l’errore … In this case, the compressor continues to operate. • Check the characteristic of the fin temperature thermistor. Do not use a manual setup for outdoor address. Comment:*document.getElementById("comment").setAttribute( "id", "abe2a4a0573d283839df61f45f8cb3e2" );document.getElementById("dee70f76f0").setAttribute( "id", "comment" ); Save my name, email, and website in this browser for the next time I comment. Therefore, it is important always to have on hand a reliable manual with necessary information. Se visualizzi l’errore E04, vuol dire che tado° non riesce a connettersi al nostro server. EVH SPACE Reversible heat pump water cooled horizontal indoor installation ductable 30-10-13 21-101 M27B40A6-05(EC1) INSTALLATION AND MAINTENANCE MANUAL 1) No jumper cap inserted on the control board. digital display area shows “E2” and FAN indicator light flashes at 1Hz. Now you’re ready to try the troubleshooting tips suggested by the manufacturer. The table below contains error codes for air conditioners made by the Dublin-based manufacturer of heating, ventilating and air conditioning systems Trane Inc. Error 01 EEPROM communication error-- Please Contact Customer Care, Compressor Failure error or refrigerant leakage, Error 02 OutDoorUnit Error -- Please Contact Customer Care, Error 03 Filter choke error -Clean the filter, Error 04 Room temp sensor failure -- Please Contact Customer Care, Cool mode or Dry mode: Unit operate with Compressor OFF. Però dal tipo di errore mi sa tanto di collegamento falso tra un sensore e • The power of follower unit is not turned on. 2) Refrigerant metering device malfunction. There is none o( outdoor terminal resistance, or there are two or more resistances. Se si dispone di un modello Midea AC per interni o esterni, gli elenchi dei codici di errore e le definizioni dei guasti sono riportati di seguito. Condizionatore d'aria Midea che mostra un codice di errore? Invece … • Room C gas pipe temperature thermistor characteristic. • Check the amount of gas and the refrigerant cycle. To find out what’s going on with your air conditioner, check the error code on the block display, remote controller or center unit 7-segment display. • Indoor evaporator temperature sensor malfunction. Check indoor P.C. This indicator turns on after PURE operation has been performed for approximately 1000 hours. When the compressor operation has been interrupted by overcurrent protection continuously three times within 1 minute after start-up, the compressor stops operation. Fan mode: Operates as per user setting, Error 06 Indoor temp sensor failure -- Please Contact Customer Care, Error 08 Communication error -- Please Contact Customer Care, Error 09 Low battery please change the battery. Compressor Discharge High Temperature Protection, Power Supply is Not Stable and Voltage Range too large, Communication Failure or mis-wired between Indoor/Outdoor. The 1st generation (VP1) applies NEC 180° sine wave plan and indoor control. Founded in 1945, Electra is one of the global leaders in High class and advanced Air conditioning and heat pump systems. This indicates the communication is not happening. Below there is a table with Everstar portable air conditioner error codes. Communication error between Application and indoor unit, Regular communication error between indoor master and follower units and between main and sub units, Disconnection, short of discharge temp. Heating and cooling LED blink 11 times at the same time, Temperature sensor malfunction of carbon fin. The tenant states the air conditioner has a green light which flashes, and a red light which also flashes. 1) loose or bad connection between sensor and control board. Outdoor unit delivery line sensor short-circuited/ disconnected, Current overload cause frequency decreased, Exhaust overload cause frequency decreased, High temperature(heat mode) cause frequency decreased, Tube temperature overload cause frequency decreased. 2) Check the drain sensor. Room-A gas pipe temperature thermistor abnormality. But without a good manual is very difficult to determine the cause of failure. If the problem still exists, then switch off the power and contact the nearest customer service center. Open or short circuit of outdoor condenser pipe, outdoor ambient temperature & compressor temperature sensors. The indicator may turn on if the plasma pure filter is not securely attached. (Exclusive of 2P unit). Condensation on the back of the indoor unit is automatically collected and drained out. The appliance has a self diagnosis system to identify a number of malfunctions. ), Indoor Evap Coil Temperature Sensor Malfunction, 1) Loose or bad connection between sensor and control board, 2) Indoor Evap Coil temperature sensor damaged, Gas valve temperature sensor is open/short circuited, 1) No jumper cap inserted on the control board, 2) Incorrect or damaged jumper cap on control board, 3) Indoor and outdoor units are not compatible, Communication wire error or electronic expansion valve malfunction, Wrong connection of communication wire or malfunction of electronic expansion valve, Compressa High Discharge Temperature Protection, 2) Supply voltage is too low and system load is too high, 1) Communication cable is mis-wired between indoa and outdoor units, 2) Indoor a Outdoor control board malfunction, Mode conflict (Indoor units calling for simultaneously Heating and Cooling). 1 5 minutes again (depending on the function setting). 2) Indoor coil temperature sensor damaged. (Protection will be released at 'lOO'C or below.). Measure the resistance value with universal meter, Internal ambient temperature sensor malfunction, Heating and cooling LED blinks 7 times at the same time. Daikin air conditioners have an advanced function of self-diagnostics. Make good use of this function for various checks. This category only includes cookies that ensures basic functionalities and security features of the website. Duplication of outdoor line addresses • Line address setup fault codes occurred after the connection between Ui. • Room D gas pipe temperature thermistor characteristic. • Indoor ambient temperature sensor is mal- function. REPAIR TECHNIQUE 3) If the other repair methods didn't help you, you will most probably need to replace the faulty control board. Sometimes when the air conditioner is broken, it is enough to know the cause of the failure to fix it easily without help of repairman. .appena lo accendo se ne va in P1..e noto che neanche parte lunità esterna..da precisare che durante lestate mi dava questo problema ma poi resettandolo ripartita. • Unplug for ten minutes and then re- start unit. Pump Down or Gathering Refrigerant Status, Indoor Ambient Temperature Sensor Malfunction. valve, debris), Compressor High Discharge Temperature Protection. > l'errore e101 viene definito come errore di comunicazione interna. Versatile and easy to install, most wall air conditioning units have a filter which destroys funghi, collects duct in the air, bacteria and viruses which provides healthy clean air for the occupants. The company Electrolux is widely known. sensor (TH), Case thermostat operation. The tables below will help you to understand the cause of the failure and fix the problem yourself. When over current is applied to the power module, the compressor stops and restarts in 3 minutes. Indoor condensate pan is full and needs to be drained. When indoor pipe temperature exceeds 55°C during heating, the compressor operates at reduced frequency. The temperature setting is too low (during heating operation). 3 repairing. Ciao ilSanto, benvenuto nella nostra Community. - The Evaporator Temperature Sensor is off or short-circuit. The owner of the air conditioner model MPM1-10CE-BB6 of this brand could get a lot of useful information from the table. Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. After check, return each bit of Dip switch to OFF position. 2) Incorrect or damaged jumper cap on control board. Use an appropriate collection pan. Reset the circuit breaker to ON. Exceeded No of connected indoor units or exceeded capacity. Some parts may expand or shrink due to temperature fluctuations, and this can result in a slapping sound. • If the power of follower unit is not turned on. When the water has been completely removed, please start the unit again. 2) Supply voltage is too low and system load is too high. Setting error, indoor and outdoor unit abnormal, Heating and cooling LED blink 12 times at the same time. Reset the Control Panel: Like a computer's memory chip or a DSL modem, an air conditioner control panel gets corrupted by continuous use and has to be reset.For GE models, as well as others, all you have to do is unplug the unit, leave it unplugged for at least 1 minute, and plug it back in. In caso negativo, riavviare il router per resettare la rete Wi-Fi. Too much refriqerant or Hiqh Ambient conditions or low airflow. Goldair GCPAC314 air conditioner manual is a good example. Il condizionatore d'aria portatile visualizza il codice "P1" (PI) Codice errore P1; Si applica a : Condizionatore portatile; Risoluzione: 1. If the error occurs continuously, the unit requires qualified inspection. Condizionatore: Errore E7: Roger: 6/19/12 6:13 PM: Salve, dopo qualche anno di onorato servizio, il condizionatore cinesino marchiato Hinno Hit appena acceso mostra a display l'errore "E7". Outdoor electronic control P.C. If the resistance is normal, replace the indoor controller board. If "F1" continues to appear call to arrange for product inspection and repair. It is not possible to set the desired temperature, the air conditioner turns on, but there is no an airflow or you see a strange error code on the display. board failure). Questo indica che la condensa dell'acqua deve essere scaricata usando le … Inverter start-up error: P1: High voltage of capacitor in main inverter circuit: P4: Radiation fin thermistor abnormality: System: U0: Low pressure drop due to refrigerant shortage or electronic expansion valve abnormality: U2: Power supply insufficient or instantaneous failure: U3: When the temperature changes sharply, the indoor or outdoor unit may make a strange noise (such as a tit-tack noise or flowing noise) because of the expansion/contraction of parts or change in refrigerant flow. Condensation on the back of the indoor unit is automatically collected and drained out. The tables below provide explanations for the error codes for air conditioners made by the Japanese multinational corporation Toshiba. The louver is not at the correct position. While on DRY and FAN modes, it shows the room temperature. Means defrosting status. The temperature setting is too high (during cooling operation). 2) Reactor filter or PFC capacitor malfunction. turn on the power. When the high pressure exceeds 2.75MPa (28 kgf/cm2-G), the compressor operates at reduced frequency. To clear the error, disconnect the breaker and wait about 4 hours to ensure that the capacitors have discharged completely. Float circuit, Disconnection, Coming-off, Float switch contact error. The unit starts automatically after approx. 2) Outdoor ambient temperature sensor damaged. Outdoor Coil Temperature Sensor Malfunction, 2) Outdoor coil temperature sensor damaged, Outdoor Discharge Temperature Sensor Malfunction, Quantity Of Group Control Indoor Units Setting Error, DC Bus Voltage Level Dropping Malfunction. Questo indica che la condensa dell'acqua deve essere scaricata usando le … najim July 19, 2020. one time my NIKAI split ac came E5, then I called technician. Thanks Greg Hancock, Your email address will not be published. Panasonic f11 fault code. 1) Loose connections between fan motor and control board. No one likes to overpay and waste a time. If the resistance is normal, replace the indoor con-troller board. Intanto, per non saper né leggere né scrivere, stacca l'alimentazione (proprio la spina, o l'interruttore generale) per un minuto, e poi riprova. Check if the resistance of compressor and resistance to ground is normal. Is your air conditioner of Chigo brand faulty? There are derivative models, e.g. board. The burner remains very hot (CO2 too high). board connectors. Indoor unit or outdoor unit makes a strange noise. They describe in detail the possible causes of failure and the way of troubleshooting. Il codice P1 indica che il contenitore d'acqua inferiore è pieno. After inside gas pressure comes down, it will fjnct on normally. When the refrigerant is flowing, a hissing sound or gurgling sound can result. When the discharge temperature exceeds 110’C, the compressor operates at reduced frequency. Transmission circuit error at interface side (P.C. Connection between multiple refrigerant lines: SW30 bit 2 of the connected header unit is turned on only in one line. Page 116 DRENAGGIO CONDENSA Quando vi è un'eccessiva condensa di acqua all'interno dell'unità, il condizionatore d'aria locale si arresta e mostra un codice di errore "P1" con un allarme. Spostare con cura l'unità in una posizione di scarico, rimuovere il … No address when indoor unit first time power on, Communication error between indoor and outdoor units, Frequency conversion module protection (reserved), Compressor overflow (four times) (reserved), Main board and display board communication fault, T3 sensor fault or T4 or digital compressor discharge temperature sensor fault (reserved), Indoor and outdoor communication fault (reserved), Phase sequence error or phase missing (reserved), Power supply overvoltage and under voltage protection, Communication fault between the outdoor unit and the mast, Communication is interrupted for more than 2 minutes , 20 minutes after the initial power-on or within 20 minutes, AC over-voltage/under- voltage protection, Display P6 protection for 3 times within 30 minutes, Unable to restore unless a second power-on, Display P2 protection for 3 times within 30 minutes, Display P4 protection for 3 times within 100 minutes, Display P9 protection for 2 times within 10 minutes, 3 times of P3 protection occurs within 60 minutes, Display H5 after 3 times of P2 protection within 30 minutes, 3 time of P4 protection appears within 100 minutes and then H6 occurs, 3 times of P6 protection appears within 30 minutes and then H4 occurs, Display H9 after 2 times of P9 protection within 10 10 minutes, 5 minutes continuous fault on hot air system at area A, Indoor and outdoor unit communication failure, Pipe temperature sensor in the evaporator (T2) fault, Pipe temperature sensor in the evaporator (T2B) fault, Indoor unit with line controller communication failure, Signal transmission error (between indoor and outdoor units), Signal transmission error (between indoor unit and remote controller), Operation halt due to the freeze protection function or high pressure control, Heat exchanger temperature thermistor abnormality, Discharge air temperature thermistor abnormality, OL activation (IT activation) or High discharge pipe temperature, Operation halt due to discharge pipe control function, Outside air thermistor or related abnormality, Discharge pipe temperature thermistor or related abnormality, Heat exchanger temperature thermistor or related abnormality, Gas pipe temperature thermistor or related abnormality, Heat radiation fin thermistor or related abnormality, Freeze-up protection control or heating peak-cut control, Moving part of electronic expansion valve (Y1E, Y3E) abnormality, Outdoor temperature thermistor (R1T) abnormality, BP liquid or gas pipe thermistor abnormality, Discharge pipe thermistor (R2T) abnormality, Suction pipe thermistor (R3T, R5T) abnormality, Outdoor heat exchanger thermistor (R4T) abnormality, Outdoor liquid pipe thermistor (R7T) abnormality, Subcooling heat exchanger gas pipe thermistor (R6T) abnormality, High voltage of capacitor in main inverter circuit, Low pressure drop due to refrigerant shortage or electronic expansion valve abnormality, Power supply insufficient or instantaneous failure, Transmission fault code between indoor unit and BP unit, Transmission error between remote controller and indoor unit, Transmission error between main and sub remote controllers, Transmission error between indoor unit and outdoor unit in the same system, Address duplication of central remote controller, Transmission error between centralized remote controller and indoor unit, System abnormality refrigerant system address undefined, Transmission error between outdoor unit and BP unit. If the display disappears, operate the air conditioner according to the following “Confirmation of error log” for confirmation. Heating and cooling LED blink 8 times at the same time. EVH SPACE Reversible heat pump water cooled horizontal indoor installation ductable 30-10-13 21-101 M27B40A6-05(EC1) INSTALLATION AND MAINTENANCE MANUAL The F11 fault code signals a problem in the heating/cooling changeover valve. The unit can now be used as usual. The 2nd generation (VP2) applies TI DSP 180° sine wave plan and outdoor control. No user input needed. 3) Indoor and outdoor units are not compatible. Per risolvere il problema sarà sufficiente seguire i seguenti passaggi: Verificare che il Wi-Fi sia attivo e che altri dispositivi riescano, mediante esso, a connettersi a internet. Questi codici di errore ti aiuteranno a capire che cosa sta causando l'errore sul tuo climatizzatore. Thanks to this manual, the owner of the air conditioner of this brand can independently determine the cause of failure and understand whether he can fix the problem on his own. Indoor / outdoor units communication protection, Open or short circuit of outdoor temperature sensor (T4), Open or short circuit of room (T1 ) or evaporator temperature sensor (T2), Over voltage or too low voltage protection. A good manual could help. Necessary cookies are absolutely essential for the website to function properly. Function will recover automatically. ", Error 15: Outdoor EEPROM parameter reading error - Please Contact Customer Care, Error 19: IPM module failure - Please Contact Customer Care, Error 20 :High/ Low Voltage protection -- Please Contact Customer Care, Error 23:Compressor position protection -- Please Contact Customer Care, Outdoor Condenser coil temperature sensor error, Error 26: Outdoor Condenser coil temperature error -- Please Contact Customer Care, System is abnormal, check if the evaporator and condenser is dirty and blocked, Indoor pipe temperature sensor malfunction, Is it loose? • This error message in the cooling function refers to too high ambient temperatures and in the heating function to too low ambient temperatures. Perhaps one of the tables below could help you to save your money and time. Each of them refers to a specific model of Aux air conditioner. 2) Loose connections between reversing valve and control. Wait for about 10 minutes, the fault may be removed automatically, if not, switch the power supply to the air conditioner off and on. When the power is turned on or the air conditioner is stopped, the vertical air louvers may make a rattling sound or shuttling sound. sensor (TL), Disconnection, short of suction temp. CODICI DI ERRORE visualizzati: E1 - errore del sensore di umidità: disconnettere l’alimentazione dell’unità e riconnettere. The plasma pure filter may make a humming, clicking, or buzzing sound when it is dirty. Se si dispone di un modello Midea AC per interni o esterni, gli elenchi dei codici di errore e le definizioni dei guasti sono riportati di seguito. After address was decided, all the indoor units do not correctly response after power-ON in outdoor unit. Local controller failure - unable to transmit, Master indoor unit receives no data to A-B, Indoor unit (except twin slave) receives no communications from outdoor unit; can also include klixon on discharge pipe of outdoor unit, 2 local controllers connected on a group - both configured as masters, Communications failure between master indoor unit and slave indoor unit or units, Indoor unit TCJ (Liquid) sensor error (Open or Closed circuit - resistance is measured in kΩ, Indoor unit TC2 (Vapour) sesnor error (Open or Closed circuit - resistance is measured in kΩ, Outdoor unit TD (Discharge) sesnor error (Open or Closed circuit - resistance is measured in kΩ, Outdoor unit TE (Coil) sesnor error (Open or Closed circuit - resistance is emasured in kΩ, Outdoor unit TO (Ambient) sesnor error (Open or Closed circuit - resistance is measured in kΩ, Indoor unit TA (Return Air) sesnor error )Open or Closed circuit - resistance is measure in kΩ, Outdoor unit inverter compressor over current detected, Master outdoor unit over current detected shortly after start up, Current detected on Master outdoor unit whilst idle, Outdoor unit Low pressure detected by Ps sensor (0.2 bar -n 2.9 psig), Indoor unit Duplicated master indoor units in a group, Indoor unit in a group of units previously addressed as a single unit - check addressing, Indoor units addresses not set - check addressing, Indoor units capacity not set (check DN Code 11), Outdoor unit IPDU error (Number of detected IPDU units is reduced), Input on indoor PCB CN80 circuit for 1 minute, Outdoor unit High discharge temperature (TD1 exceeded 115°C), Outdoor unit High pressure switch activated (Detected by high temperature on TE sensor on digital/super digital inverter units), Outdoor unit PCB heat sink overheated (Temperature over 90°C recorded), Indoor unit fan motor error - detected by feedback circuit, Wrong change in temperature recorded (4 way valve error), Outdoor unit Giant transistor short circuit, Outdoor unit Compressor error detected by feedback circuit, Indoor unit Group control follower unit error / duplicated central control addresses, Central control Sending error in TCC-Link central control device, Central control Receive error in TCC-Link central control device, Batch alarm for general purpose equipment interface, No communication from remote controller (including wireless) and communication adapter. The products 2P and higher are mainly developed for two generations. board.). 1) Wrong wiring of indoor/outdoor connecting wire. Smells absorbed in the wall, carpet, furniture, clothing, or furs are coming out. The problem of my unit it run and after a min. The unit may stop operation or continue to run in a safety condition. Signal transmission error (Remote controller does not respond to indoor controller signal.). full DC inverter unit, inverter floor-standing unit and LC plan. SEASON'S GREETINGS. • Room temperature outside the function range: • Temporary error of start temperature. • Unplug for ten minutes and then turn on unit. This message could appear in heating mode if the condensate drain hose is not attached or is blocked. 30 minutes. In addition to the check code on the remote controller of the indoor unit, a trouble of the outdoor unit can be diagnosed by 7-segment display of the control P.C. Page 116 DRENAGGIO CONDENSA Quando vi è un'eccessiva condensa di acqua all'interno dell'unità, il condizionatore d'aria locale si arresta e mostra un codice di errore "P1" con un allarme. Float switch operation. If “E5" is still displayed call to arrange for product inspection and repair. The compressor indicator (red) lights up constantly, and the indoor fan stops, The unit is shifting from heating mode to defrost, The indicator will turn off within ten minutes and return to heating mode, It is on during operation. L'errore E36 corrisponde a un errore del sensore di corrente. In addition, the fan speed changes. najim July 19, 2020. one time my NIKAI split ac came E5, then I called technician. • Check the contact of P. C. board connectors. Check and modifies disconnection of indoor/outdoor communication line. Index: Split System AC Error Codes, Multi System AC Error Codes, Portable AC Error Codes; When an error occurred in the air conditioner, an error code and indoor UNIT No. • Temporary error on measuring output temperature. Each user can determine an error of the Daikin air conditioner on his own. A white mist of chilled air or water is generated from the outdoor unit. Just look into the table below. If temperature within operating range clean the filters. One of the sensors on the appliance is faulty. The error code is only displayed during the operation. Wall mounted air conditioning is the most popular type of air conditioning system. sensor (TD), Disconnection, short of heat exchanger temp. These cookies do not store any personal information. • If error code appears on the indoor unit display, turn off the appliance and disconnect from power supply, then contact the nearest Whirlpool Authorized Service Center, and tell customer service about the indicated error code. Indoor unit or outdoor unit makes a strange noise. When the state with low discharge temperature of which 50°C in COOL and 48.4 or less in HEAT for 20 minutes, the compressor operates continuously. When a short or open circuit occurs in the Room-B gas pipe temperature thermistor. :smileysad: Potresti fornirci il modello esatto del tuo condizionatore, in modo da poter rispondere con precisione alla tua domanda? To replace the control board, you have the option of calling a technician, which can, depending on where you're from, cost you around 400 USD.